Abbott Hematology Instruments

Abbott CELL-DYN 1800
Cell-Dyn 1800

The CELL-DYN 1800 has been developed to continue Abbott Laboratories' commitment to laboratory hematology analyzers. The CELL-DYN 1800 is specifically designed to meet the needs of the world's changing laboratory environment. This new 3-part leukocyte differential analyzer has an expanded data log to handle up to 10,000 samples, a bar code reader for more reliable data transcription and a smaller size to easily fit into today's laboratories. With over 12,000 CELL-DYN 3-part differential analyzers in use around the world, the CELL-DYN 1800 is building on years of experience and is the perfect size analyzer for any hematology lab.

The CELL-DYN 1800 provides fast, accurate results and differential screening with sophisticated data management, in a compact, easy-to-use system.
  • 18*-parameter automated system
  • 3 part differential
  • Open and Pre-Dilute Modes
  • 30 µl open mode (40 µl pre-dilute mode) sample requirement
  • Color LCD Monitor with three histogram displays
  • Cyanide-Free Lyse reduces biohazard and safety risks
  • Results in only 60 seconds
  • 10,000 specimen data storage with graphics
  • Inkjet printer for clean, clear reports

*PCT and PDW are not reportable in the USA.

Abbott CELL-DYN 1700
Cell-Dyn 1700

The CELL-DYN 1700 was developed to address hematology needs in today's changing laboratory environment. Ease of use, low maintenance, closed-tube sampling, small sample requirements, and high reliability are features expected in the modern hematology lab. New challenges have made fast access to results, sophisticated data management, and simplification of data interpretation necessary to meet the increasing demands of current clinical practice. The CELL-DYN 1700 can deliver all these features to any size hematology lab that demands the latest in technology.

TheCELL-DYN 1700 provides fast, accurate results and differential screening with sophisticated data management, in a compact, easy-to-use system

  • 18-parameter* automated system
  • Three-part leukocyte differential
  • Optional closed sampling system
  • Graphical display with three histograms
  • 30 microliter sample requirement
  • 60 seconds for a Complete Blood Count
  • 5,000 specimen data storage with graphics

*PCT and PDW are not reportable in the USA.


Abbott CELL-DYN 3200
Cell-Dyn 3200

The CELL-DYN 3200 incorporates high-resolution flow cytometry with Multi-Angle Polarized Scatter Separation (MAPSS™) to fully automate the CBC and five-part differential.

  • Walkaway automation with 24 parameters*
  • Two-dimensional laser platelet and red cell analysis
  • 3-D MCV measurement ensures accurate RBC analysis
  • Five-part leukocyte differential
  • 71 samples per hour
  • Available as a single-tube closed sampling system or 50-position sample loader
  • Resistant RBC mode minimizes interference
  • Single-tube closed sampler with bar-code reader
  • Full data management with data storage for 10,000 specimens with graphics
  • Single-step dilution reticulocyte procedure

*PCT and PDW are not reportable in the USA

The CELL-DYN 3200 sets a new benchmark for innovative, compact design. MAPSS technology assures the highest level of result accuracy and precision. The CELL-DYN 3200 is a contemporary vision of hematology automation for today's laboratory. This system offers features found in few other hematology systems, regardless of price.


Abbott CELL-DYN 3700
Cell-Dyn 3700

The CELL-DYN 3700 combines optical light scatter and impedance technologies, including Multi-Angle Polarized Scatter Separation (MAPSS™) to fully automate the CBC and five-part differential, to improve performance and productivity in critical-care environments.

  • Walkaway automation with 25 parameters*
  • Five-part leukocyte differential
  • 90 samples per hour
  • Available as a single-tube closed sampling system or 100-position sample loader
  • Single-step dilution reticulocyte procedure
  • Full data management with data storage for 10,000 specimens with graphics
  • Enhanced hardware and software for future capabilities

*PCT and PDW are not reportable in the USA.

The CELL-DYN 3700 uses the revolutionary concept of complementary technologies to increase accuracy and efficiency in the busy hematology laboratory. By performing simultaneous optical and impedance measurements on up to 10,000 white blood cells, the system can select the correct methodology for the existing pathology. The comprehensive data management program and low maintenance requirements make the CELL-DYN 3700 system the optimal choice for a wide variety of laboratory situations.


Abbott CELL-DYN 4000
Cell-Dyn 4000

The CELL-DYN 4000 uses the power of multiple technologies to bring new automated parameters to the hematology laboratory. Fluorescent detection of RNA allows for fully-automated, random-access reticulocyte results. Fluorescent DNA staining of nucleated red blood cells ensures accurate white blood cell values and provides a reportable NRBC count. Two-dimensional Optical platelet counts with automatic verification by focused-flow impedance provides enhanced information for platelet analysis. If abnormal samples or high-volume workload are part of your daily challenge, the CELL-DYN 4000 will deliver quantifiable economic and clinical benefits for your leading-edge laboratory.

CELL-DYN 4000 offers state-of-the-art measurements of argon-ion laser light scatter (MAPSS™ technology) and focused-flow impedance, combined with two-color fluorescent flow cytometry for the laboratory on the leading edge.

  • Walkaway automation with 41 parameters*
  • Fully automated reticulocyte analysis with IRF
  • Five-part leukocyte differential
  • Fluorescent DNA staining of nucleated red blood cells
  • Autoloader with multiple type tube capacity
  • 106 samples per hour, including differential
  • Optical and impedance platelet measurement
  • Fully automated Monoclonal Ab testing
    • CD 3/4/8 Testing
    • CD 61 Testing

*WVF, PDW, PLTs, PLTl, v4, v8, and v4/8 are not reportable in the USA.